<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15396</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: Dvac generator unable to maintain the vacuum level. Switch to Dvac pump.
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
This error is only a warning. The plot should be able to finish.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
This error is only a warning. The machine should be able to use the vacuum
pump to continue operation. However, if this error is ignored for a long time,
the vacuum pump's operational life may be shortened.
If this error recurs frequently, check to see if dvac generator
is functional by the monitor command "dvac generator on|off".
</text></DescriptionText>
</ServiceInformation>
<Cause>
Leakage in the media seal.
</Cause>
<Cause>
Malfunctioning dvac generator hardware.
</Cause>
<Cause>
Improperly adjusted dvac generator threshold "alproof dvgt cal"
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/dvac.xml</LinkAddress><LinkTitle>Command: dvac</LinkTitle></Link>
<Link><LinkAddress>../nvs/alproof_cfg_dvgi.xml</LinkAddress><LinkTitle>NVS: alproof dvgi</LinkTitle></Link>
<Link><LinkAddress>../nvs/alproof_cal_dvgt.xml</LinkAddress><LinkTitle>NVS: alproof dvgt</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:08 2008 PST
</Updated>
<Links>
</Links>
</Error>